Categories
-
New Products (194)Specials (20)Bestsellers (25)Brine Measurement (1)Cleaning & Sanitation (7)Assorted Test Reagents (67)Canadian Test Kits (1)CHEMetrics Visual Kits (1)Control Timers (1)Controllers; Boiler (4)Controllers; Cooling Tower (8)Corrosion Monitoring (9)Electrolytic Generators (1)Email & Text Alerts (1)FREE SpeedStir (1)International and Custom Orders (7)Laboratory Analyses (5)Laboratory Equipment (34)LaMotte Test Kits (3)Laundry Products (10)Leak Detection (2)Legionella Test Kits (4)LMI Roytronic A Series Chemical Metering Pumps, Milton Roy (24)LMI Roytronic Excel AD Series Chemical Metering Pumps, Milton Roy (24)LMI B Series Chemical Metering Pumps, Milton Roy (24)LMI C Series Chemical Metering Pumps, Milton Roy (1)LMI P Series Chemical Metering Pumps, Milton Roy (91)Megatron SS Controllers (7)Meters (Hand Held) and Accessories (22)Myron L Meters by Taylor (9)Palintest Kits (0)Products; Boiler (2)Products; Boiler Layup (3)Products; Chemical (9)Products; Closed Loop (19)Products; Cooling Tower (4)Products; Equipment (33)Products; Microbio Control (23)Products; Specialty (8)Products; Unique (9)Pumps (174)Refractometers (2)Removed from Store (1)Services (4)Sessile Bacteria Products (5)Taylor Test Kits; Industrial (163)Taylor Test Kits; Midget Comparators (27)Taylor Test Kits; Pool & Spa (47)Taylor Test Kits; Slide Comparators (37)Taylor Reagent Packs (3)Test Cabinets (8)Test Kits, Miscellaneous (16)Test Kits; Private Label (35)The Suggestion Box (1)Used or Surplus Equipment (2)Water Meters (4)Your Products (1)
Manufacturers
Product Details
|
0611 Sample Filtration Pretreatment Kit
SKU: LE0-06110-MAS
|
Overview
10% Discount on all orders.
Get free shipping on orders over $100.00.
We accept Visa, MasterCard, American Express and Discover.
For additional terms on this prouct click on the Terms of Sale Tab (above).
The 0611 is our Sample Filtration Pretreatment Kit..
View an on line video on our Syringe Filtration System.
The pretreatment of a test sample to remove any suspended particulate matter which will interfere with the test is required at times. The sample should be filtered prior to running the analysis to remove excess particles, iron, turbidity, or other easily filtered interfering objects.
To use the test::
- Completely remove the plunger from the syringe.
- Unscew the cilter cartridge and insert filter paper circle onto the screened palte.
- Screw the filter housing back together tightly.
- Screw the tip of the syringe into the large threaded hole of the filter cartridge.
- Set the syringe/cartridge assembly in the 25 mL marked sample bottle (NOT INCLUDED - provided in a test kit).
- Fill the syringe/cartridge assembly with the sample to be tested.
- Carefully insert the plunger and gently press downward to filter. Continue pressing down on the plunger until the air bubble, trapped between the sample and the plunger is forced thru the filter. A steady even pressure on the plunger is the optimum filter rate.
This kit includes the following components:
| Component | Description | Quantity | ||
| 6257 | FILTER PAPER, 2.5 cm WHATMAN NO. 5 OR EQUIVALENT | 1 | ||
| 6249 | FILTER HOUSING, FOR USE WITH 2.5 cm FILTER CIRCLES | 1 | ||
| 6247 | SYRINGE, PLASTIC 30 ml | 1 |
Prices for the Continental 48 states of the USA only. K1554