Categories
Sale Item
The Megatron SS SSPRE
$2893.00 Add to cart to see price

Pump, Series C

SKU: PP0-PMPSC
Price:
Add to cart to see price

PSI/GPD:
CONTROL OPTIONS:
VOLTAGE:
HEAD AND FITTINGS:
SEAT AND O-RINGS:
BALL CHECK:
CONNECTION:
Text Area:
Qty: - +
   - OR -   

FOR CURRENT DISCOUNTS, SEE TERMS OF SALE TAB (LEFT).
With few exceptions, you get free shipping on orders over $100.00, lower 48 States of the USA.
We accept Visa, MasterCard, American Express and Discover
.
For PayPal Transactions we can email a Request for Funds
.
Purchase Orders will be accepted for Domestic US Companies with an approved Credit Application.

Two Year Factory Warranty!

We will meet or beat anyone's price on Advantage Controls equipment.

CONTACT US FOR PRICE QUOTATION.

Advantage Controls Microtron Series C Pumps

The Series C pumps feature adjustable stroke length with fixed speed. 10:1 turndown.

Series C metering pumps provide reliable, economical chemical addition for a wide variety of applications. Metering accuracy is achieved with microprocessor controlled preset speed and double ball guided checks. A rugged housing with control cover is suitable for outdoor installations. Available in outputs up to 30 GPD and 250 PSI.

  • Built-in Priming Valve
  • Guided Double Ball Checks
  • Circuit Protection
  • Fixed Speed
  • Low Cost

DRIVE SELECTIONS

The pump models that you can select from the first dropdown menu are:

  • Model C130 - 30 GPD at 110 PSI
  • Model C120 - 20 GPD at 110 PSI
  • Model C115 - 15 GPD at 110 PSI
  • Model C110 - 10 GPD at 110 PSI
  • Model C105 - 5 GPD at 110 PSI
  • Model C217 - 17 GPD at 250 PSI
  • Model C215 - 15 GPD at 250 PSI
  • Model C210 - 10 GPD at 250 PSI
  • Model C205 - 5 GPD at 250 PSI
  • Model C202 - 2 GPD at 250 PSI

The control options that you can select from the second dropdown menu are:

  • X = (Standard) Control (Default Selection)
  • E = External Pace
  • F = Hall Effect flow meter input (divides by 9)

The voltage options that you can select from the third dropdown menu are:

  • 1 = (Standard) 120 Volt USA plug, 5.5’ long (Default Selection)
  • 2 = 240 No plug
  • 3 = 240 South American plug
  • 4 = 12 Volt DC (60 PSI max; Output not affected)
  • 5 = 240 Volt USA plug
  • 6 = 240 Volt Korean plug / 60 cycle
  • 7 = 240 Volt Australian plug

WET END SELECTIONS

The head and fitting options that you can select from the fourth dropdown menu are:

  • K = Kynar (Default Selection)
  • S = 316SS*
  • M = Kynar Head w/ SS MNPT Valves*

* M and S options must have P connection code

The seat and O-ring options that you can select from the fifth dropdown menu are:

  • V = Viton (Default Selection)
  • F = Teflon
  • H = Hypalon

The connection options that you can select from the sixth dropdown menu are:

  • 1 = 3/8” Tubing for 75-200 psi (Default Selection)
  • 2 = 1/4” Tubing for 250 psi
  • K = Kynar suct / disch tubing
  • P = 1/4” MNPT
  • Q = 1/4” MNPT disch / 1/4” FNPT suc
  • R = 1/4” FNPT
  • U = 3/8” Black UV resistant
  • V = Clear flex 3/8” suct tubing

The ball check options that you can select from the seventh dropdown menu are:

  • C = Ceramic (Default Selection)
  • D = Ceramic (single on discharge)
  • S = Stainless

OTHER OPTIONS

We are thinking that the following is getting a little too exotic and complicated for auto selection and are best addressed as a custom order. You can select and contact us for pricing on up to three of the following:

  • 4 = Blue Housing
  • 5 = Green Housing
  • 6 = Conformal Coating
  • C = Dust Cover (Series C only)
  • E = External Stop
  • F2 = Paddlewheel Flow Meter, Kynar construction
  • P ON/OFF Power Switch
  • R = Remove Stroke Adjust
  • S = 3-Function Valve (25 lbs load, anti-siphon & check)

If you need further customization than what you see here, Contact Us.

Chemical Compatibility
When building the liquid end portion of a pump model it is critical that the materials selected are compatible with the product to be pumped. Listed below are some common chemicals and recommended liquid end codes. Example: Sodium Hypochlorite (chlorine) A130X1-KVCV.

Chemical Code
ACETIC ACID, 5-10% KHC
ALUMINUM SULFATE ‘alum’ KHC
AMINES, 0 - 35% KFC
AMINES, > 40% SFS
AMMONIA, 10% KHC
BROMINE KFC
CALCIUM HYPOCHLORITE KVC
DBNPA KFC
ETHYLENE GLYCOL KFC
FERRIC CHLORIDE KFC
FERRIC SULFATE KFC
GLUTARALDEHYDE KFC
HYDROCHLORIC ACID, 0 - 37% KFC
HYDROGEN PEROXIDE, 0 - 30% KVC
INHIBITING PHOSPHONATES KFC
ISOTHIAZOLINE KFC
NITRIC ACID, 0 - 20% KVC
PHOSPHORIC ACID, 0 - 100% KFC
POTASSIUM CHLORIDE KFC
SODIUM BI-CARBONATE ‘soda ash’ KFC
SODIUM BI-SULFATE KFC
SODIUM BI-SULFITE KFC
SODIUM BROMIDE KFC
SODIUM CARBONATE KFC
SODIUM HYDROXIDE, ‘caustic’, 0 - 50% KHC
SODIUM HYPOCHLORITE KVC
SODIUM NITRATE KFC
SODIUM SILICATE KHC
SODIUM SULFATE KHC
SODIUM SULFIDE KHC
SULFURIC ACID, 10 - 75% KFC
SULFURIC ACID, 95 - 100% KFC

MicroTron Series C metering pumps provide reliable, economical chemical addition for a wide variety of applications. Metering accuracy is achieved with microprocessor controlled preset speed and double ball guided checks. A rugged thermoplastic NEMA 4X housing allows for outdoor installations. The Series C pumps are available in outputs up to 30 GPD and 250 PSIG. The manual stroke length adjustment provides a simple turn down on all models.

Key Features: • Single Output Adjustment • NEMA 4X Style Enclosure • Guided Double Ball Checks • Circuit Protection • Thermal Overload Protection • Priming Valve Standard • Microprocessor Fixed Speed

There are many other options available. Contact us  with your unique requirements.

Prices for the Continental 48 states of the USA only.

Your Name:
Your Email:
Friends Name:
Friends Email:
Subject:
Message:
Verification: